Skip to content
HYPERPCB

CAPABILITIES

HDI PCB Capability

HyperPCB builds high-density interconnect PCBs from 1+N+1 to 4+N+4 and ELIC, with laser microvias down to 50 µm, 0.10 mm mechanical drills and 1:1 blind via aspect ratio — up to 48 layers with ±7% controlled impedance.

HDI PCB Capability — representative build

SPECIFICATIONS

Capability & tolerance chart

HDI PCB Capability — standard vs advanced.
ParameterStandardAdvanced
HDI Structures1+N+1, 2+N+2, 3+N+3, 4+N+4, ELICAny-layer HDI by project review
Maximum Layer CountUp to 48 layers
Minimum Line Width / Spacing1.57/1.57 mil1.38/1.38 mil for advanced high-density products
Minimum Mechanical Drill3.94 mil
Minimum Laser Via2.76 – 2.95 mil standard HDI1.97 mil for advanced HDI
Minimum Laser Via Pad8.86 milSmaller pads by project review
Through-Hole Aspect RatioUp to 16:1
Blind Via Aspect RatioUp to 1:1
BGA PitchDown to 11.8 mil, subject to design and process review
Via FillingCopper-filled, resin-filled, filled and capped vias
Via StructuresStacked, staggered, blind, buried and via-in-pad
Controlled Impedance±8% typicalTighter control by stack-up review
Copper Thickness1/3 oz – 8 oz, depending on layer structure
Lamination CyclesMultiple sequential lamination cycles supported
Surface FinishesENIG, ENEPIG, OSP, immersion silver, immersion tin, hard gold, soft gold, gold finger

Sequential lamination without registration surprises

Every HDI build adds lamination cycles, and each cycle is an opportunity for layer-to-layer drift. We image with LDI, drill microvias by laser on the same panel reference, and measure registration between cycles rather than at final inspection, so a 4+N+4 build lands inside the same pad windows as a 1+N+1.

Choosing a structure for your BGA pitch

A 0.5 mm pitch BGA usually escapes on 1+N+1. Below 0.4 mm, or with several fine-pitch devices sharing a region, 2+N+2 and stacked or staggered microvias start to pay for themselves. Send the densest footprint on the board and we will come back with the cheapest structure that routes it.

Verification on buried structures

Buried microvias cannot be inspected optically once laminated, so coupons are cross-sectioned and 3D X-ray is used on the finished board to confirm fill, wetting and stack alignment. Records ship with the lot.

FAQ

Frequently asked questions

RELATED

Related capabilities

Ready to build?

Ready to build?

Upload your Gerber files for a free DFM review and a quote within 24 hours. Mutual NDA available.