Skip to content
HYPERPCB

CAPABILITIES

PCB Manufacturing Capability

HyperPCB fabricates single-sided through 48-layer boards up to 1000 × 600 mm: 2.5/2.5 mil trace and space standard, 35/35 µm advanced, 0.10 mm drills, 50 µm laser vias, ±7% impedance. Every lot is released with AOI and TDR records.

PCB Manufacturing Capability — representative build

SPECIFICATIONS

Capability & tolerance chart

PCB Manufacturing Capability — standard vs advanced.
ParameterStandardAdvanced
PCB TypesSingle- and double-sided, multilayer, HDI, flexible, rigid-flex, high-frequency, high-speed, heavy copper, metal-core
Maximum Layer CountUp to 48 layers
HDI Capability1+N+1, 2+N+2, 3+N+3, 4+N+4, ELICAny-layer HDI by project review
Maximum Board Size1000 × 600 mm
Finished Board Thickness3.94 – 472 milDepends on board type and project requirements
Minimum Line Width / Spacing2.5/2.5 mil standard process1.38/1.38 mil for advanced high-density products
Minimum Mechanical Drill5.91 mil standard production3.94 mil for advanced HDI
Minimum Laser Via2.95 mil standard HDI1.97 mil for advanced HDI
Through-Hole Aspect RatioUp to 20:1
Blind Via Aspect RatioUp to 1:1
Copper ThicknessInner up to 12 oz / outer up to 14 oz on heavy copper projects
Controlled Impedance±10%±7% by stack-up and material review
Special ProcessesBlind and buried vias, via-in-pad, resin-plugged vias, filled and capped vias, back drilling, controlled-depth routing, step grooves, edge plating

SURFACE FINISHES

Available surface finishes

HASLLead-free HASLENIGENEPIGOSPImmersion SilverImmersion TinHard GoldSoft GoldGold FingerSelective ENIG + OSPElectrolytic Gold / Silver

One capability chart, not two

The standard column is what we run on production lines every day; the advanced column is what we hold with process controls and longer cycle times. Nothing on this page is a marketing ceiling — if your stack-up sits in the advanced column we will say so in the DFM review and price the extra process steps openly.

Where the tolerances come from

Line width and spacing are set by laser direct imaging rather than film, which removes registration drift across a 1000 × 600 mm panel. Impedance is held by controlling the laminate we fabricate ourselves: dielectric thickness and resin content are known before lamination, so the ±7% window is a measurement we verify by TDR, not an estimate.

What to send for a quote

Gerber RS-274X or ODB++, a drill file, the layer stack-up if you have one, material and finish requirements, quantity and target lead time. If the stack-up is open we will propose one. A mutual NDA can be signed before you upload.

FAQ

Frequently asked questions

RELATED

Related capabilities

Ready to build?

Ready to build?

Upload your Gerber files for a free DFM review and a quote within 24 hours. Mutual NDA available.